Seguridad

Skip to main content
NeuroPace, Inc.
  • Patients
  • Providers
  • Corporate
  • nSight
  • PDMS
  • Take the Quiz
  • Clinical Trials
  • Learn About the RNS System
    • Drug-Resistant Epilepsy
    • The RNS System
  • See if you Qualify
    • Take the Quiz
    • Find a Center
  • Hear from Patients
    • Patient Stories
    • How Data Helped
    • RNS Community Chat
  • Resources
    • Find a Center
    • RNS Community Chat
    • Education (brochures, infographics, videos)
    • Helpful Links
    • Clinical Trials
    • Contact Us
  • Blog
  • Current Patients
    • Manuals
    • MRI Safety
    • How-to Videos
    • Living with the RNS System
    • Current Patient FAQ
  • Learn About the RNS System
    • Drug-Resistant Epilepsy
    • The RNS System
  • See if you Qualify
    • Take the Quiz
    • Find a Center
  • Hear from Patients
    • Patient Stories
    • How Data Helped
    • RNS Community Chat
  • Resources
    • Find a Center
    • RNS Community Chat
    • Education (brochures, infographics, videos)
    • Helpful Links
    • Clinical Trials
    • Contact Us
  • Blog
  • Current Patients
    • Manuals
    • MRI Safety
    • How-to Videos
    • Living with the RNS System
    • Current Patient FAQ
Press enter to begin your search

NeuroPace® RNS® System

Breve declaración

Indicaciones de uso
RNS System es una terapia auxiliar que ayuda a reducir la frecuencia de las convulsiones en personas mayores de 18 años con convulsiones de comienzo parcial, que se sometieron a pruebas de diagnóstico que detectaron no más de 2 focos de origen de la epilepsia, que no respondieron a dos o más medicamentos antiepilépticos, y que actualmente sufren convulsiones frecuentes e incapacitantes (convulsiones parciales motoras, convulsiones parciales complejas o convulsiones secundariamente generalizadas).

RNS System demostró ser seguro y efectivo en pacientes con un promedio de 3 o más convulsiones incapacitantes por mes en los últimos tres meses (con al menos dos convulsiones por mes), y no fue evaluado en pacientes con convulsiones menos frecuentes.

Contraindicaciones
RNS System está contraindicado para pacientes con alto riesgo de complicaciones quirúrgicas, con dispositivos médicos que dan energía eléctrica al cerebro, y para quienes no pueden (o no tienen la asistencia necesaria para) hacer funcionar correctamente el monitor remoto o el imán NeuroPace . Los pacientes con un dispositivo RNS System implantado, no pueden realizarse los siguientes procedimientos médicos:

  • Terapia electroconvulsiva (TEC)
  • Estimulación Magnética Transcraneal (EMT)
  • Procedimientos diatérmicos (cualquier tratamiento que use radiación electromagnética, corrientes eléctricas u ondas ultrasónicas para producir calor en los tejidos corporales)

Advertencias y precauciones
RNS System no es compatible con cables o generadores de pulsos que no sean NeuroPace. Si el programador o el monitor remoto se usan de manera incorrecta pueden producir choques eléctricos. No volver a esterilizar ni reusar los productos implantables.

Información de seguridad de RMN
RNS Neuroestimulador modelo RNS-320: Se puede hacer una resonancia magnética a pacientes con RNS System (con Neuroestimulador modelo RNS-320) solo en las condiciones específicas de manejo seguro que se detallan en las Pautas para RMN para RNS System. Hacer un escaneo en diversas condiciones puede dañar o provocar una disfunción del dispositivo y un grave riesgo para el paciente, como daño permanente al cerebro que puede causar daños severos, coma o la muerte.

No es seguro realizar una resonancia magnética con RNS Neuroestimulador modelo RNS-300M de RNS System no es seguro para realizar una RMN. Tener un RMN con un Neuroestimulador RNS-300M implantado puede causar daños severos o la muerte.

Componentes Externos de RNS System: Todos los componentes externos y accesorios de RNS System, tales como el imán, la tableta RNS, el programador NeuroPace , el monitor remoto NeuroPace y la vara son peligrosos para realizar una RMN y pueden representar un riesgo explosivo para el entorno de la RM; por lo tanto, deben mantenerse fuera de la sala donde se encuentre el RMN.

Uso clínico
Solo neurocirujanos con la experiencia adecuada en implantes subdurales y estereotático de electrodos intraparenquimales y el tratamiento quirúrgico de epilepsia intratable, pueden implantar el RNS System en Centros Integrales de Epilepsia. Solo neurólogos y neurocirujanos con la experiencia adecuada en el manejo de epilepsia intratable y en la detección del foco de la epilepsia pueden usar el RNS System. Deben completar un programa de capacitación en RNS System de NeuroPace y demostrar capacitación específica sobre epilepsia, monitoreo con electroencefalograma por video, interpretación de electrocorticogramas (ECoG), farmacología de antiepilépticos y selección de pacientes para cirugía de epilepsia. En algunos casos, los neurólogos que cumplen con los requisitos de experiencia y certificación pero no trabajan en centros integrales de epilepsia pueden ser calificados por NeuroPace para realizar la programación posterior al implante.

Implantación quirúrgica
La implantación de RNS System y los riesgos asociados con un procedimiento quirúrgico pueden causar, entre otros efectos, infección, hemorragia intracraneal, daño en los tejidos, dolor temporal en el lugar del implante, pérdida de líquido cefalorraquídeo, seroma y parálisis.

RNS System y Terapia:
No se estudió la seguridad y efectividad en mujeres embarazadas. No se conocen en profundidad los efectos de la estimulación cerebral a largo plazo. Las interferencias electromagnéticas (IEM) fuertes pueden ocasionar lesiones graves o muerte del paciente, daño en el tejido cerebral, pérdida o cambio del control de síntomas, otra operación, activación o desactivación de la estimulación o aumento momentáneo de la estimulación que el paciente puede sentir. Además, las IEM (como los dispositivos de detección de seguridad y la identificación con radiofrecuencia) pueden disparar la estimulación programada para el paciente y aparecer como artefactos de detección en los registros de los electrocorticogramas. RNS System podría interactuar con dispositivos cardiacos implantados y ocasionar una respuesta inadecuada del dispositivo o dañarlo. Puede haber otros procedimientos quirúrgicos que surjan por un mal funcionamiento de la batería, cortocircuito eléctrico, circuito abierto, rotura del cable, falla del aislamiento del cable, daño como resultado de un traumatismo de cabeza o migración del cable. Si el neuroestimulador se rompe o perfora debido a fuerzas externas, puede producir un daño cerebral grave a causa de la exposición a los químicos de las pilas. El paciente debe recopilar datos de su neuroestimulador una vez por día y enviar esos datos al sistema de administración de datos del paciente una vez por semana.

Entorno Médico
Se debe evitar la electrólisis en la cabeza y el cuello. Antes de administrar litotripsia extracorporal por ondas de choque o fuentes de radiación alta, el médico debe consultar al médico que recetó RNS System. Lea el manual del usuario para comprender los pasos que se deben seguir antes, durante y después de las tomografías computarizadas (TC).

Posibles eventos adversos
>En ≥2,5 % de los pacientes ocurren reacciones adversas graves y las más relevantes informadas en los estudios clínicos de RNS System, incluyen monitoreo con electroencefalograma, infección, cambio en las convulsiones, retiro del dispositivo médico, muerte, daño o revisión de los cables del dispositivo, toxicidad de antiepiléptico, hemorragia, eventos psiquiátricos, estado epiléptico y lesiones relacionadas con las convulsiones. Consulte la etiqueta del producto para obtener información detallada sobre otras reacciones adversas.

Venta solo con receta. Consulte la etiqueta del producto en www.NeuroPace.com para obtener información detallada sobre indicaciones específicas, contraindicaciones, advertencias, precauciones y reacciones adversas.

DN 1017114 Rev 2
Fecha de revisión: 2020-02

  • Safety Information
  • Legal
  • Privacy Policy
1-866-726-387624-hr Support Line

PATIENTS

  • Drug-Resistant Epilepsy
  • The RNS System
  • Hear from Patients
  • Is It Right for You?
  • Current Patients
  • Resources

PROVIDERS

  • Product
  • Clinical Benefits
  • Actionable Insights
  • Patient Selection
  • Education & Training
  • Resources

CORPORATE

  • In The News
  • Press Releases
  • Leadership
  • Careers
  • Contact Us
  • FCOI Procedure
  • PATIENTS

    Safety
  • PROVIDERS

    Legal
  • INVESTORS

    Privacy Policy
  • CORPORATE

1-866-726-3876 24-hr Support Line

© 2025 NeuroPace, Inc..

This site uses cookies to store information on your computer. Some are essential to make our site work; others help us improve the user experience. By using the site, you consent to the placement of these cookies. You may at any time change the settings regarding cookies. Read our privacy statement to learn more. Do not sell my personal information.

X
Manage consent

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
CookieDurationDescription
cookielawinfo-checbox-analytics11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checbox-functional11 monthsThe cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checbox-others11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-advertisement1 yearSet by the GDPR Cookie Consent plugin, this cookie is used to record the user consent for the cookies in the "Advertisement" category .
cookielawinfo-checkbox-necessary11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-performance11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
JSESSIONIDsessionThe JSESSIONID cookie is used by New Relic to store a session identifier so that New Relic can monitor session counts for an application.
viewed_cookie_policy11 monthsThe cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
CookieDurationDescription
s_ccsessionThis cookie is set by Adobe Analytics to determine if cookies are enabled or not.
Performance
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
CookieDurationDescription
ac_enable_tracking1 monthThis cookie is set by Active Campaign to denote that traffic is enabled for the website.
Analytics
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
CookieDurationDescription
_ga2 yearsThe _ga cookie, installed by Google Analytics, calculates visitor, session and campaign data and also keeps track of site usage for the site's analytics report. The cookie stores information anonymously and assigns a randomly generated number to recognize unique visitors.
_gat_UA-55828317-31 minuteA variation of the _gat cookie set by Google Analytics and Google Tag Manager to allow website owners to track visitor behaviour and measure site performance. The pattern element in the name contains the unique identity number of the account or website it relates to.
_gid1 dayInstalled by Google Analytics, _gid cookie stores information on how visitors use a website, while also creating an analytics report of the website's performance. Some of the data that are collected include the number of visitors, their source, and the pages they visit anonymously.
CONSENT2 yearsYouTube sets this cookie via embedded youtube-videos and registers anonymous statistical data.
demdex5 months 27 daysThe demdex cookie, set under the domain demdex.net, is used by Adobe Audience Manager to help identify a unique visitor across domains.
Advertisement
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
CookieDurationDescription
_fbp3 monthsThis cookie is set by Facebook to display advertisements when either on Facebook or on a digital platform powered by Facebook advertising, after visiting the website.
fr3 monthsFacebook sets this cookie to show relevant advertisements to users by tracking user behaviour across the web, on sites that have Facebook pixel or Facebook social plugin.
VISITOR_INFO1_LIVE5 months 27 daysA cookie set by YouTube to measure bandwidth that determines whether the user gets the new or old player interface.
YSCsessionYSC cookie is set by Youtube and is used to track the views of embedded videos on Youtube pages.
yt-remote-connected-devicesneverYouTube sets this cookie to store the video preferences of the user using embedded YouTube video.
yt-remote-device-idneverYouTube sets this cookie to store the video preferences of the user using embedded YouTube video.
Others
Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet.
CookieDurationDescription
AMCV_98CF678254E93B1B0A4C98A5AdobeOrg2 yearsNo description
AMCVS_98CF678254E93B1B0A4C98A5AdobeOrgsessionNo description
DrupalVisitorMobilesessionNo description available.
FASRVsessionNo description available.
FORMASSEMBLYsessionNo description available.
prism_7986813311 monthNo description
SAVE & ACCEPT
Powered by CookieYes Logo

Step 1 of 7

14%
    The RNS System is for individuals 18 and older who have focal epilepsy and have tried two or more medications without finding seizure control.
  • Based on your answers, your patient might benefit from the RNS System.

    Get your profile and a list of questions to ask your doctor.

  • Unfortunately it appears your patient is not an appropriate candidate for the RNS® System at this time.

  • The RNS® System is intended for patients who have undergone diagnostic testing that localized no more than 2 epileptogenic foci.

    If your patient has not undergone diagnostic testing, search here to find a comprehensive epilepsy center that can evaluate your patient, including determining if the RNS System is right for them.

  • If you are interested in learning more about the RNS® System, you can have an RNS® System professional contact you by filling out the form below:

  • By filling out this form, you are agreeing to the terms of our privacy policy. This form is intended for US residents only.

    By clicking submit, you are agreeing to receive communications from NeuroPace. You can unsubscribe at any time.

    * Required fileds

Share your Story: Terms and conditions

By filling out the form and submitting your story (and/or photograph), you are agreeing to the following:

  1. NeuroPace may review the information and any photographs you provide for potential publication on our website.
  2. If NeuroPace decides to use your story, we will contact you and ask you to sign a release for a version of your story to be used on the NeuroPace website, Facebook, Instagram, Twitter and/or LinkedIn. Unless you sign the release, we will not publish the story, your name, or the photographs you provided.
  3. Regardless of whether we publish your story, we will add your name and e-mail address to the NeuroPace email list to hear from us about product updates, upcoming events and other relevant information. We will not sell your information to third parties. 
  4. Our use of your information is subject to our Privacy Policy, which you can access here.
neuropace logoLogo Header Menu
  • Patients
  • Providers
  • Corporate
  • nSight
  • PDMS
  • Take the Quiz
  • Clinical Trials